IFM流量计-IFM流量传感器工作原理

发布日期:2022-10-09 点击率:102 品牌:易福门_IFM

IFM流量计-IFM流量传感器工作原理
德国IFM流量计算程序
计算程序是计算流速,流量或管内直径的工具。
首先在选择框中点击要计算的参数。这两个自由参数然后自动准备作为输入字段。
然后可以输入两个缺失参数的值,并通过下拉框添加合适的单位。
选择框“在传感器尖端包含传感器”:对于小直径(<25mm),由于插入管道中的传感器尖端的位移,自由管道横截面严重变化。因此,传感器安装深度的指示对于小直径管道特别重要。传感器端部面积的计算基于ifm型SI5000的直径。安装深度由管道内部指定。这是约。 12毫米。然而,对于特殊的T形件或适配器,这个尺寸可以改变。
对于管内直径,请参考附表“根据DIN2440的螺纹管”。点击标记的链接可以打开一个单独的窗口。
在输入所有必要的值后,程序将通过点击“计算”按钮开始。
结果用所有参数和单位表示。
指示更改的参数并按下“计算”按钮后,可以开始新的计算
IFM流量计-IFM流量传感器工作原理

Flow sensors / flow meters

  • For liquids and gases

  • Versions for the use in hygienic applications

  • Variable process connection using adapters

  • Flow monitoring also for aggressive media

    Program for flow calculation

    Program description

    The calculation program is a tool to calculate flow velocity, flow rate or inside pipe diameter.

  • First click on the parameter to be calculated in the selection box. The two free parameters are then automatically prepared as input field.

  • You can then enter the values for the two missing parameters and add the suitable unit via a drop-down box.

  • Selection box "Include sensor in the calculation tip": For small diameters (<25mm) the free pipe cross-section changes critically as a result of the displacement of the sensor tip which is inserted into the pipe. The indication of the installation depth of the sensor is therefore specially important for small pipe diameters. The calculation of the area of the sensor tip is based on the diameter of the ifm type SI5000. The installation depth is specified from the pipe inside. This is approx. 12 mm. This size can however change for special T-pieces or adapters.

  • For the inside pipe diameter please refer to the enclosed list "threaded pipe according to DIN2440". A click on the marked link opens a separate window with this table.

  • After all necessary values have been entered the program starts by clicking on the button "calculate".

  • The results are indicated in a table with all parameters and units.

  • You can start a new calculation after indicating the changed parameters and pressing the button "calculate".